Other Name: | Earphone Jack | Ambient Temperature: | -25℃~70℃ |
---|---|---|---|
Contact Resistance: | 30mΩ Max. | Insulation Resistance: | 100MΩ Min. |
Rated Load: | DC12V 1A | Relative Humidity: | ≤85% |
Highlight: | aviation wire connectors,stereo headphone jack |
4pin 6.35mm stereo headphone jack, female socket for DJ headphones
Material:
Terminal | Brass |
Outer contact | Brass |
Housing | PBT |
Back cover | PBT |
Environmental performance:
Project | Test methods and conditions | Specification and requirements |
High temperature test | Placed in the outlet temperature of +70 ± 2 °C in the oven, a duration of 96 hours, then remove the condition at room temperature 1 to 2 hours. | Subject to the requirements |
Low temperature test | Placed in the outlet temperature of -25 ± 2 °C low temperature case, the duration of 96 hours, then taken out at room temperature 1 to 2 hours. | Subject to the requirements |
Humidity test | Placed in the outlet temperature of +40 ± 2 °C, relative humidity 90-95% RH in constant hot box, a duration of 96 hours, then remove the condition at room temperature 1 to 2 hours. | Subject to the requirements |
Temperature cycling test |
Placed below the outlet conditions of the chamber, and then taken out at room temperature 1 to 2 hours. |
Subject to the requirements |
Resistance to soldering heat test | Placed in the socket solder the conditions listed below: Solder temperature: 255 ± 5 °C Soldering time: 5 ± 0.5 S |
Subject to the requirements |
Can be defended test | The socket pin head 2.5mm metal parts immersed in temperature of 245 ± 5 °C solder to maintain 3 ± 0.5 seconds. | Solder dipped parts can be covered by more than three quarters. |
Salt spray test | Placed in the socket to test the following conditions: Test temperature: 35 ± 2 °C Test time: 48 ± 2 h Saline gravity: 5 ± 1% (by weight) Spray device during the test will be able to produce uniform fine droplets. |
Subject to the requirements |
Mechanical performance:
Project | Test methods and conditions | Specification and requirements |
Insertion force | With a load cell or similar device, plug socket power measurement, the standard should be slowly inserted into the plug socket, plug to test 5 times. | 5~30N |
Withdrawal force | With a load cell or similar device, plug socket power measurement, the standard should be slowly inserted into the plug socket, plug to test 5 times. |
3~30N
|
Terminal strength | Lead terminal socket of the socket should be able to withstand the force along the axial end of 5N, with time for 5 seconds. | Terminal no loosening |
Mechanical life | Using the standard plug in the case of no load 10 times per minute rate of insertion and removal 5000. | Subject to the requirements |
Packaging | Outlet should be installed in the dry, moisture, dust and mold in the box, packing box outside the box plugged in and can not shake the box to be placed on quality certification and the packing list. |
Packing list and the appearance of the box should indicate the appropriate product name, model number and date of flag to be clear and intact. | |
Transport | Packing boxes of socket, to avoid the rain and snow poured directly under the conditions of attack, can use any means of transport delivery. |
Storage | Packing boxes of sockets should be at ambient temperature-10°C~+40°C, relative humidity ≤ 80%, ambient air is not acidic, alkaline or other corrosive gases, warehouse storage. |
Socket storage period not to exceed 200 days. |